Client Background
The Rock Inn, a well-established pub located in a suburban residential area, required a specialised cooling solution for its beer cellar. With the venue operating in close proximity to neighbouring homes, any new system needed to deliver both high performance and minimal noise disruption.
Project Overview
AJ Taylor was contracted to design and install a purpose-built beer cellar cooling system to maintain a stable storage temperature of 10–11°C year-round. A critical project requirement was compliance with strict local noise regulations, given the site’s location within a densely populated residential setting.
Execution
System Design & Selection
After assessing site conditions and operational needs, we specified and installed the Marstair CXEA50 evaporator paired with a CKA35 condensing unit. This UK-manufactured system offered:
-
Precise Temperature Control tailored for beverage storage.
-
Low-Noise Operation, thanks to a factory-fitted quiet fan kit.
-
Energy Efficiency, using R410a refrigerant and a high CoP.
-
Compact Design, suitable for the restricted cellar and outdoor areas.
Indoor Unit (CXEA50) Installation
-
Ceiling-mounted above keg storage with direct airflow distribution.
-
Condensate pipe connected to a floor gully with trap to prevent backflow.
-
Uniform cooling layout ensured even temperature across the cellar.
Outdoor Unit (CKA35) Installation
-
Wall-mounted using anti-vibration brackets on the rear exterior.
-
Acoustic enclosure installed on three sides to reduce sound propagation while maintaining airflow.
-
Soft-start controller added to minimise startup noise and electrical load.
-
Cabling and controls neatly routed through internal trunking to preserve external aesthetics.
Result
The system passed all local residential noise compliance checks, and a detailed commissioning report was completed to support long-term maintenance and warranty coverage.
Client Feedback
“The new cellar cooling system is quiet, efficient, and does exactly what we need without disturbing our neighbours. We’ve had no complaints and seen better stock consistency since installation.”
— Manager, The Rock Inn
Conclusion
The installation of the Marstair CXEA50 and CKA35 system provided a high-performing, low-noise solution perfectly suited for a sensitive suburban setting. AJ Taylor’s precise planning, careful acoustic considerations, and professional installation ensured full regulatory compliance and excellent client satisfaction.
Key Takeaways
-
Always evaluate ambient noise levels when installing refrigeration near residential zones.
-
Use acoustic enclosures and low-noise fan kits for condensing units.
-
Add soft-start modules to minimise acoustic and electrical disruptions.
-
Prioritise routine maintenance to maintain long-term efficiency and low operating sound levels.